中文网站正在持续更新中,请密切关注我们康肽生物的最新动态,或点击访问右上角的英文官方网站 www.phoenixpeptide.com
PHOENIX PHARMACEUTICALS, INC. TOP HOME PAGE
Top » Catalog English Version | My Account | 联系我们 | China



 多肽



 标记多肽 



 多肽激素文库



 抗体 



 免疫试剂盒 



 生物标志物阵列 



 多肽样品检测



 自定义肽链合成及GMP



 产品目录索取



 样品准备



 提问和解答


Ghrelin RIA
More information


Ghrelin Level
Fasting plasma Ghrelin (Human) 514+/-63 pg/ml n=24 Otto B, et al. Eur J Endocrinol 2001 Nov;145(5):669-73
Fasting plasma Ghrelin (Human) 1057+/-95 pg/ml (anorectic patients Otto B, et al. Eur J Endocrinol 2001 Nov;145(5):669-73
Ghrelin (Human) 307 +/- 164 [Prader-Willi syndrome (PWS)] DelParigi A., et al. J Clin Endocrinol Metab 2002 Dec;87(12):5461-4
Ghrelin (Human) 109 +/- 24 fmol/ml DelParigi A., et al. J Clin Endocrinol Metab 2002 Dec;87(12):5461-4
Fasting serum ghrelin levels (Human) 270 +/- 102 pmol/liter Haqq AM, et al. J Clin Endocrinol Metab 2003 Jan;88(1):174-8
Fasting serum ghrelin levels (Human) 429 +/- 374 pmol/liter [Prader-Willi Syndrome (PWS)] Haqq AM, et al. J Clin Endocrinol Metab 2003 Jan;88(1):174-8
Fasting serum ghrelin levels (Human) 139 +/- 70 pmol/liter (Obese group) Haqq AM, et al. J Clin Endocrinol Metab 2003 Jan;88(1):174-8
Fasting plasma ghrelin 87+/-28 pmol/liter (Pima Indians) Tschop M, et al. Diabetes 2001 Apr;50(4):707-9
Fasting plasma ghrelin 129+/-34 fmol/ml (Caucasians) Tschop M, et al. Diabetes 2001 Apr;50(4):707-9
fasting healthy lean children (NC) 426.0; 183.0-618.0 pg/ml Bellone S., et al. J Endocrinol Invest 2002 May;25(5):RC13-5
fasting obese children (OBC) 229.5; 162.5-339.5 pg/ml Bellone S., et al. J Endocrinol Invest 2002 May;25(5):RC13-5
Fastin healthy lean adults (NA) 380.5; 257.7-551.7 pg/ml Bellone S., et al. J Endocrinol Invest 2002 May;25(5):RC13-5


Circulating Ghrelin Levels Are Decreased in Human Obesity

 

Lean 

Caucasians

Obese 

Caucasians

Lean Pima 

Indians

Obese Pima 

Indians

n 7 8 7 8
Sex-Female 3 4 3 4
Sex-Male 4 4 4 4
Age (Years) 32 ± 11 30 ± 7 33 ± 4 32 ± 5
Body weight (kg) 71.4 ± 9.8 109.8 ± 16.8 70.3 ± 9.6 109 ± 15.2
BMI (kg/m2) 25.4 ± 2.3 38.2 ± 4.8 24.0 ± 1.9 37.9 ± 6.6
Body fat (%) 22 ± 9 35 ± 7 24 ± 7 35 ± 5
Plasma Ghrelin (fmol/ml) 155 ± 25 106 ± 23 95 ± 13 80 ± 36
Plasma Glucose (mg/dl) 87 ± 7 91 ± 4 89 ± 6 95 ± 7
Plasma Insulin (uU/ml) 4 ± 3 10 ± 3 6 ± 3 18 ± 10
Plasma Leptin (ng/ml) 8 ± 7 53 ± 47 10 ± 9 35 ± 27
Tschšp, M., et al. Diabetes 50, 707-709, 2001



EK-031-30



RK-031-30


Extraction of plasma sample is not necessary with Phoenix's 

human Ghrelin RIA Kit 

Time of Use* Week 0 Week 2 Week 4
1 x 5.75pg (57.5pg/ml) 12.3pg (123pg/ml) 7.65pg (76.5pg/ml)
1/2 x 1.88pg 6.53pg 3.41pg
1/4 x   2.59pg 1.61pg
1/8 x   0.98pg 0.58pg

* Kits used in Week 0 were used within 2 days of manufacture. All kits used in Week 2 and 4 were stored as dry power (not reconstituted) at 4¡C.

**100 µl of plasma (non-extracted, normal human subjects) was used to perform the RIA. To calculate the level of Ghrelin-like immunoreactivity, the level obtained by extrapolation of the standard curve must be multiplied by 10 to obtain the level at 1 ml (ex. 12.3 pg x 10 = 123 pg/ml).

 

Stability of Ghrelin (Human) RIA Kit

(at least 3 weeks in liquid form)

Time of Rehydrate B/T (%) R/T (%) ED20 (pg/tube) ED50 (pg/tube) ED80 (pg/tube)
hour 1 0.04 0.44 23.78 8.74 3.14
Day 2 0.04 0.52 14.19 5.51 2.19
Week 1 0.05 0.50 23.72 8.18 2.65
Week 2 0.03 0.43 38.21 11.88 4.57
Week 3 0.03 0.44 31.82 11.12 3.64
Rehydrate one kit contents with RIA buffer keep them at 4¡C. Kits was used in above scheduled time. 

Stability of Ghrelin (Human) RIA Kit

(at least 4 weeks in dry form)

Time of Use* B/T (%) R/T (%) ED20 (pg/tune) ED50 (pg/tune) ED80 (pg/tune)
Week 0 0.05 0.37 20.90 5.78 1.99
Week 2 0.03 0.45 19.03 8.25 3.14
Week 4 0.03 0.35 15.75 6.28 2.27
* Kits used in Week 0 were used within 2 days of manufacture. All kits used in Week 2 and 4 were stored as dry power (not reconstituted) at 4¡C.
 
Phoenix strongly recommends using the RIA kit as soon as possible. Always store the unused kit as dry power at  4¡C if not used immediately. Never store reconstituted kit components as they are unstable. Use of stored reconstituted kit components to perform RIA may yield poor and unacceptable results.

Phoenix's Ghrelin (Human) RIA Kit detects "total" Ghrelin, including Ser3- octanoyl and Ser3-des-octanoyl Ghrelins.

 

%ghrelin%


分类搜索
关键字搜索
按字母搜索
A B C D E F G H I J K L M N
O P Q R S T U V W X Y Z

Copyright © 2024 PHOENIX BIOTECH