Many research models such as knock-out
mice and patient sample often provide miniscule sample volume for
detection. Our chip solves this problem. (30 to 100ul
required)
Economical
$8/spotted antibody. Each dual-padded slide allows
detection and
comparison of 40 obesity biomarkers.
Convenient
Easy to use. Save time by measuring up to 80 biomarkers
simultaneously.
Versatile
Measure human serum, plasma, CSF, tissue extract
and more!
Chemiluminence or
Fluorescence
Read results with Chemiluminence imager, camera, or x-ray film
Standard microarray reader at 635 nm for Cy5 image
Picture of the
product
See links below for custom formats
Positive control
Negative control
Each slide contains 2 nitrocellulose pads (or
wells). One pad can have 40 capture antibodies in addition to 38
positive control spots and 2 negative control spots. *Dimensions of
glass slide are 2.5cm x 7.6cm
Obesity
Biomarker Chip (Human)
Antibody
*
Antibody
*
Antibody
*
Antibody
*
ACTH
A1,B1
CRF
C5,D5
IMD / AM-2
A5,B5
Oxytocin
G8,H8
Adiponectin
A2,B2
C-Peptide
C4,D4
KiSS-1
E2,F2
Peptide YY
E8,F8
ADM-Pro-N-20
A3,B3
Endorphin Beta
A9,B9
Leptin
G5,H5
PrRP-31
G3,H3
ADM (1-50)
A4,B4
Ghrelin
C8,D8
MCH
E1,F1
Relaxin (INSL-7)
E0,F0
AGRP
A6,B6
GLP-1
C6,D6
MSH Alpha
C10,D10
Retinol Binding Protein
G0,H0
Amylin
A7,B7
GLP-2
C7,D7
Neuromedin U
E3,F3
Resistin
G2,H2
Apelin-12
A8,B8
Glucagon
C9,D9
NPB-29
E5,F5
TNF-Alpha
G4,H4
Bombesin
A10,B10
GHRF
G7,H7
NPW, prepro
E10,F10
Urocortin
E9,F9
Calcitonin
C1,D1
IGF-1
G9,H9
NPY
E7,F7
Visfatin
G1,H1
CART
C2,D2
IL-6
G10,H10
NPW
E6,F6
-
-
Cholecystokinin
C3,D3
Insulin
G6,H6
Orexin A
E4,F4
-
-
Obesity
Biomarker Chip (Rat, Mouse)
Antibody
*
Antibody
*
Antibody
*
Antibody
*
ACTH
A1,B1
CRF
C4,D4
INSL-3
G6,H6
Orexin A
E4,F4
Adiponectin
A2,B2
Desnutnin
C5,D5
IMD / AM-2
A5,B5
Oxytocin
G8,H8
ADM-Pro-N-20
A3,B3
Endorphin Beta
A9,B9
KiSS-1
E2,F2
PACAP
G10,H10
ADM (1-50)
A4,B4
Ghrelin
C8,D8
Leptin
G5,H5
Peptide YY
E8,F8
AGRP
A6,B6
GLP-1
C6,D6
MCH
E1,F1
PrRP-31
G3,H3
Amylin
A7,B7
GLP-2
C7,D7
MSH Alpha
C10,D10
Resistin
G2,H2
Apelin-12
A8,B8
Glucagon
C9,D9
Neuromedin U
E3,F3
TNF-Alpha
G4,H4
Bombesin
A10,B10
GHRF
G9,H9
NPB-29
E5,F5
Urocortin
E9,F9
CART
C2,D2
IGF-1
G10,H10
NPW
E6,F6
VIP
E10,F10
Cholecystokinin
C3,D3
IL-6
G7,H7
NPY
E7,F7
Vistafin
G1,H1
The fluorescent images of plasma derived from two
individuals using Phoenix Pharmaceuticals biomarker chip (OC-KF-002).
Increased levels of Amylin, GLP-1, Glucagon, and Leptin can be observed
from the obese individual (left panel). On the contrary, increased levels
of Adiponectin, Ghrelin and GHRF were found in the non-obese
individual.
This image was collected using GenePix 4100A by Axon
Instruments, Inc. The average duplicated spot intensities for each subject
were analyzed to reveal the over- and under- abundant plasma biomarkers in
the obese individual (delete) compared to the lean
individual.
Each Array Kit Contains:
2 Biomarker Arrayed Slides
2 Free-biotin Albumin Captured Magnetic Bead 2 Spin Columns 1 Pre-measured HABA/Avidin Mixture 1
Streptavidin-HRP
1 Chemiluminence Substrate or Fluorescence Dyes 1 Blocking Buffer 1 Assay
Buffer 1 BCA Protein Assay
1 NHS-Biotin/Biotinylation Buffer
5 Well
Covers
1 HABA/Avidin Mixture
1 Slide Chamber